POWER CONTROL SYSTEMS

 

Where Ideas and Technology Meet!
FACILITY TYPE
POWER DISTRIBUTION UNIT (28 VDC)

The Power Distribution Unit for Wide Facility Platforms, with its rich input and output features, can be used by configuring in different features in different usage areas. It distributes by operating in the voltage range of 28 VDC +/- 10% and 220 VAC +/- 10%. The apparatus for MIL-STD-810G standards extract provides the conditions defined in la. Different current values for DC and AC distribution channel has in own circuit breaker.

Technical Specifications
  • Operating Voltage: 28 VDC +/- 10% and 220 VAC +/- 10%
  • Temperature :
    • High Temperature: Method 501.5, Procedure I (Procedure II (Operation, Ambient Temperature + 44 °C)
    • Low Temperature: Method 502.5, Procedure II (Operation, Ambient Temperature: -5 °C)
  • Moisture: Method 507.5, Procedure II Figure 507.5-7
  • Vibration: Method 514.6 Category-20 Procedure-I, Figure 514.6C-3 two hours per 3 axes, functional test
  • Mechanical Shock: Method 516.6, Procedure I-Functional Shock, 20g 11ms, saw-tooth wave, three times in both directions and all 3 axes
  • Working at High Altitude: Method 507.5, Procedure II Figure 507.5-7, 95% relative humidity (non-condensing)
Device output features
  • 8 x 20A Circuit Breaker Protected DC Output
  • 9 x 5A Circuit Breaker Protected AC Output
  • Weight: 17kg
  • Dimensions: 19 '' RACK 4U
We have many products that we have developed especially in the fields of electric motor drives, power adapters, and power distribution and battery management systems.