POWER CONTROL SYSTEMS

 

Where Ideas and Technology Meet!
SUBMARINE UNINTERRUPTED POWER SUPPLY / POWER DISTRIBUTION UNIT

PDU: Power Distribution Unit and UPS: Uninterruptible Power Supply developed by PAVOTEK for Turkish Armed Forces (TAF) and to be used in AY Class Submarines. The main purpose of PDU is to activate connected devices in a certain order. The software on it determines the operation of the device for a period of about 90 seconds and in what order to power the connected units. Lithium – Ion battery is use in UPS. Normally, power from an external power source is transferred to the output. If an interruption is detected here, the battery is activated. This transition is carried out in such a way that it cannot be detected from outside and does not cause disruption.

SUBMARINE UNINTERRUPTED POWER SUPPLY
Technical Specifications
  • Power Distribution Control with 14 Semiconductor Relay Modules
  • Module board that functions as a semiconductor relay with isolated supply and communication
  • Ability to turn on and off the mosque with both RS485 communication and logic control
  • It can read current and input-output voltages, values such as card temperature and provide protection against overvoltage, overcurrent, short circuit, over temperature conditions.
  • Failure record with Flash
  • To be able to transfer the readings via RS485 communication
  • Software update via RS485
  • Reverse Voltage Protection
  • Communication and Control with PC Application over 100 Mbit Ethernet and Isolated RS232
  • Working with 180-330 VDC Main Input Supply
  • Working with 28 VDC Uninterruptible Power Supply
  • Detecting UPS Warning States and Turning the UPS On / Off
  • Analog Working Clock
  • LED Indicators According to Circuit Breaker and Relay Status
  • Ability to Provide Warning Conditions with LED and Buzzer
  • IP54 sealing level
SUBMARINE POWER DISTRIBUTION UNIT
Technical Specifications
  • 180-330 VDC Input / 28 VDC Output
  • 1800 W Nominal Output Power
  • 2000 W Output Power (for 5 minutes)
  • Inrush Power < 4800 W
  • Efficiency > 90%
  • Cooling with 3 fans
  • Air Noise <49 dBA
  • Battery Hot Swapping
  • IP54 sealing level
  • Working 5 minutes at full load with Li-ion battery
  • 32-21.5 VDC Battery Voltage Range
  • Status and Error Logging via PC Interface over Isolated RS232
  • Front panel LEDs showing the status of input-output voltage, temperature, battery capacity.
  • Isolated temperature and low battery capacity warning connection

We have many products that we have developed especially in the fields of electric motor drives, power adapters, and power distribution and battery management systems.